Menu

Revio system + SPRQ Chemistry

Reveal more with accurate long-read sequencing at scale

HiFi sequencing at scale

With a high-density SMRT Cell, up to 4 SMRT Cells per run, and 24-hour run times3, the Revio system with SPRQ chemistry delivers up to 480 Gb2,5 of HiFi reads per day, equivalent to 2,500 human whole genomes4 per year. ​

The $5006 complete, phased genome

HiFi sequencing provides small variants, structural variants, repeat expansions, methylation, and haplotype phasing from a single library and sequencing run. With a comprehensive genome, you can replace multiple assays, saving valuable time and resources while gaining deeper insights in one streamlined process.

Long-read genomes at scale, with 4x less DNA input required

SPRQ chemistry on the Revio system unlocks the ability to sequence more sample types than ever before, using just 500 ng of native DNA – without sacrificing the high throughput or exceptional quality you rely on.

On-instrument 5mC and 6mA caller for multiomic Fiber-seq chromatin assay

SPRQ chemistry, paired with Google Health DeepConsensus algorithms, delivers exceptional read accuracy plus confident 5mC and 6mA methylation detection in every run. Optimized file formats reduce data storage needs through quality value binning and smart read ordering, streamlining data handling and maximizing efficiency.

View product brochure     Get a quote

HiFi sequencing at scale

Estonia National Biobank selects PacBio to sequence 10,000 whole genomes

HiFi data generated on the Revio system will support the EU and Estonian government-funded Center for Personalized Medicine to enable discoveries across cardiology, mental and reproductive health, drug response, cancer research and rare diseases.

PacBio and GeneDx Launch Research Collaboration with the University of Washington

This study is first of its kind to compare diagnostic rates across short- and long-read sequencing platforms to understand the potential for increased diagnostic yield in neonatal care.

Ambry Genetics and PacBio Announce Collaboration to Sequence Up to 7,000 Human Genomes

Consortium selects leading genomics companies to support pediatric Mendelian Genomics Research Center Program aimed at providing insights for families battling rare diseases.

Ignite your research with SPRQ chemistry

With SPRQ chemistry, the Revio system helps you achieve more with less DNA, increasing efficiency, maximizing output, and reducing costs – empowering you to make more discoveries faster and affordably.

Reduced input, expanded application possibilities:

  • Only 500 ng DNA input
  • 4X more efficient SMRT Cell loading

Drive down genome costs:

  • 33% increased HiFi yields
  • 2 human genomes at 20X per SMRT Cell

Spark innovation:

Resolve chromatin architecture with Fiber-seq powered by on-instrument 5mC and 6mA calling, now with an increased 5mC CpG accuracy for even greater precision.

Key applications and sample throughput with SPRQ chemistry

The Revio system supports a variety of applications that benefit from accurate long HiFi reads and 500 ng input DNA requirement. Its four independent stages allow different samples and applications to be sequenced in parallel. A subset of key applications is:

Library Application Per Revio SMRT Cell
Per yeara
Expected coverageb
1-5 kb Amplicon sequencing > 1,000 > 2.5 million 50X
5-10 kb Microbial genome 384 480,000 30X
5-10 kb PureTarget repeat expansion panel 48 60,000 200X
15-20 kb Human genome 2 2,500 20X
15-20 kb Human methylation profiling 8 10,400 5X
15-20 kb Transcriptome with Kinnex full-length RNA kit 6 7,500 10 million reads
  1. Annual throughput is based on 2,500 Revio SMRT Cells for 12 hour runs; 1,250 for 24 hour runs. Adaptive loading – which increases the consistency of yield per SMRT Cell – adds about 4 hours to run time, affecting the maximum number of SMRT Cells per year. 
  2. Expected coverages are estimates. 

See what you can get from 1 SMRT Cell​   Access data sets

“HiFi long read sequencing can now produce the most comprehensive variant dataset obtainable by a single technology in a single laboratory, allowing accurate calling of substitutions, indels, STRs and SVs.”

– Kucuk et al., Genome Med, 2023

HIFI LEVEL ACCURACY AND DATA QUALITY

The Revio system with SPRQ chemistry produces exceptional read length, quality, and variant calling performance that have made HiFi sequencing so celebrated.

Reveal a more complete genome​

The complete, gapless human genome marks a new era of genomics where no region of the genome is beyond your reach. In 2021, PacBio HiFi technology was used by the Telomere-to- Telomere (T2T) Consortium to fill in those gaps.

Read length

HiFi reads are tens of kilobases long, providing the ability to resolve large variants and map to difficult regions of the genome.​

Read and base quality

The Revio system provides reliable answers through exceptional accuracy, with 90% of bases Q30+ and median read accuracy ≥Q30.​

Variant calling

HiFi sequencing with SPRQ chemistry on the Revio system delivers high accuracy variant detection, resulting in fewer sequencing errors relative to other technologies at lower coverage1.

How Revio long-read sequencing compares

PacBio Revio with SPRQ SBS sequencing Nanopore sequencing
Read length

15-20 kb5

2x150 bp 10–100 kb
Read accuracy

99.95% (Q33)1

99.92% (Q31)3

98.90% (Q19)4

Run time

24 hours2

44 hours 72 hours
Yield

120 - 480 Gb2

2,400–3,000 Gb 50–110 Gb
Coverage Unbiased Reduced at low and high (GC) Reduced in low-complexity runs

Genome completeness6

X

Variant calling – SNVs, Indels, SVs5

X
X
Areas of high homology
X
X
Phasing
X
Methylation - 5mC and 6mA Every run​ Via library prep Every run​

1. Read accuracy PacBio HiFi: precisionFDA Truth Challenge V2
2. HiFi yield specification based on HG002/GM24385 human DNA extracted with Nanobind CBB kit and prepared with SMRTbell prep kit 3.0. Run time specification is for the sequencing reaction. HiFi yield is dependent on library fragment size. Yield is typically lower for shorter libraries.

3. Illumina: HG002 2×150 bp NovaSeq library, precisionFDA Truth Challenge V2
4. ONT: Q20+ chemistry (R10.4, Kit 12), Oct 2021 GM24385 Q20+ Simplex dataset release
5. Shafin Nat Methods 2021 (https://doi.org/10.1038/s41592-021-01299-w)
6. Cheng 2021 Nat Methods (https://doi.org/10.1038/s41592-020-01056-5) and Shafin 2020 Nat Biotech (https://doi.org/10.1038/s41587-020-0503-6)

 

Workflow

Extraction

Nanobind DNA kits enable extraction of HMW gDNA from a variety of samples: saliva, cultured cells, bacteria, whole blood, tissue, plant nuclei, and insect.​

Learn more

Library prep

SMRTbell prep kit 3.0, HiFi prep kits, and application kits (Kinnex, PureTarget) support manual and automated library prep for effortless SMRTbell library creation.

Learn more

Sequencing

The Revio system offers simultaneous acquisition of 4 SMRT Cells, configurable sequencing run times to tailor to your application, and flexible run scheduling to fit your schedule.

Learn more

Data analysis

Advanced algorithms from Google Health and cutting-edge NVIDIA GPUs allow for on-board processing of sequencing data, all with reduced output file sizes.

Learn more

Simplified Consumables

The Revio system simplifies the HiFi sequencing experience with fewer consumables optimized for easy tracking and minimal waste. With workflow improvements, loading consumables takes under a minute at the instrument.

Revio SMRT Cell tray

One tray contains 4 high-density SMRT Cells.

Revio SPRQ sequencing plate

The sequencing plate provides reagents for sequencing up to 4 Revio SMRT Cells.

Order kits

A WORKFLOW BUILT FOR YOUR SCHEDULE

The Revio system gives you a vastly simplified experience with consumables and software designed for flexibility and convenience. Whether you’re a genome center or a small lab, you can enjoy:

Fast, reliable library preparation

Library prep for the Revio system supports manual and automated prep. Learn more

Rapid run setup

Sequencing plates are linked automatically to run designs through an NFC tag, enabling runs to be set up in less than one minute on instrument.

Flexibility to fit your schedule

The Revio work deck is isolated from the four sequencing stages, leaving the system available up to 20 hours per day for loading consumables for subsequent runs.

MASSIVE COMPUTE POWER

The Revio system includes powerful NVIDIA GPUs, which provide more than 20× the compute power of the Sequel IIe system, to deliver accurate, ready-to-use data directly from the instrument.​

HiFi read generation

The GPUs provide rapid turnaround time for basecalling and HiFi read generation, directly outputting HiFi reads in BAM format.

Google Health DeepConsensus

DeepConsensus uses advanced deep learning techniques to further extend the accuracy and yield of HiFi sequencing.

Methylation calling (5mC and 6mA)

Standard runs include DNA methylation status, calculated with a deep learning algorithm that processes polymerase kinetics.

Demultiplexing

All fundamental processing steps are performed on instrument, including barcode demultiplexing.

 

Image of Revio system with Google Health logo in front

More HiFi reads, more samples, more discovery

System specifications with SPRQ chemistry

The Revio system utilizes nanofabricated Revio SMRT Cells and has four independent stages, allowing sequencing of multiple SMRT Cells in parallel. The onboard compute provides accurate basecalling with Google DeepConsensus, plus methylation calling in every run.

Library
Run timea
Q30+ bases

HiFi yield per SMRT Cellb

Methylation
1-5 kb 12 hours 95% 6-8 million reads 5mC at CpG sites and 6mA for native DNAc
5-10 kb 24 hours 90% 35-70 Gb
10-15 kb 70-100 Gb
15-20 kb 100-120 Gb
20-25 kb 30 hours 85% 100-120 Gb
  1. Run time refers to the data collection step, which determines the time between processing SMRT Cells.
  2. HiFi yield is dependent on library quality and sequencing preparation procedures.  Specified yield is based on high-quality samples prepared following best practices. 
  3. The Revio 6mA caller is designed to detect methylation in the context of the Fiber-seq chromatin assay.

Download spec sheet

 

Instrument specifications

Operating environment
Temperature 19–25°C (66–77°F)
Humidity 20–80% relative humidity, non-condensing
Ventilation 13,000 BTU/hr (3,800 W)
Dimensions
W × D × H 92.7 cm (36.5 in) × 91.4 cm (36.0 in) × 174.5 cm (68.7 in)
Weight 465 kg (1,025 lb)
Floor space 243.8 cm (96.0 in) × 138.5 cm (54.5 in)
Electrical power
Power requirements 200–240 VAC at 50-60 Hz, max 5 kVA/4.8 kW/24A
Compute
Network connection 1 GbE or 10 GbE, copper
Output file format hifi_reads.bam, ~60 GB each, up to 78 TB per year

Frequently asked questions

The SPRQ (pronounced “spark”) chemistry is our newest HiFi chemistry that makes sequencing more efficient and expands HiFi sequencing to more sample types and applications. SPRQ requires only 500 ng of native DNA, which opens up even more possibilities for your projects. Plus, SPRQ helps lower genome costs by increasing HiFi yields per SMRT Cell by 33%, allowing you to sequence two human genomes at 20X coverage per SMRT Cell.

And that’s not all—SPRQ also enables deeper multiomic insights into chromatin architecture with Fiber-seq, using on-instrument 5mC and 6mA calling for greater precision in methylation detection.

The Revio system with SPRQ chemistry sequences two human genomes at 20x coverage for just $5006. Your local sales representative can provide detailed pricing in your currency.

6$500 per human HiFi genome assumes US list price of $995 for sequencing reagents for one Revio SPRQ SMRT Cell, which has an expected yield of 120 Gb, equivalent to two 20× human genomes.

The capabilities† of just one Revio SMRT Cell include:

  • Up to 120 Gb of total HiFi long-read sequencing data in 24 hours.
  • Two phased 20x human whole genome.
  • One sample with ~80 million full-length RNA isoforms using the Kinnex single-cell RNA kit.
  • 16 samples using large, targeted gene panels such as the Dark Gene.
  • 96 samples using small, targeted gene panels similar to the Long-read PGx.
  • 16 communities of metagenome assembled genomes.

† Expected coverage and throughput are estimates. Coverage and total reads/data may vary based on library quality and fragment lengths.

The Revio system outputs ready-to-use HiFi reads in BAM format. All fundamental processing steps are performed on instrument, including barcode demultiplexing.

  1. Data shown is for a single Revio SMRT Cell for HG002/GM24385.
  2. HiFi yield specification based on HG002/GM24385 human DNA extracted with Nanobind CBB kit and prepared with SMRTbell prep kit 3.0.
  3. Run time specification is for the sequencing reaction.
  4. Expected coverages and throughputs are estimates. Coverage may vary based on library quality and fragment lengths.
  5. HiFi yield is dependent on library fragment size. Yield is typically lower for shorter libraries.
  6. Currency is calculated based on reagent list pricing in USD.

See system specification sheet for more details.

This is your moment

See it all at scale with the Revio system.

Get started

Talk with an expert

If you have a question, need to check the status of an order, or are interested in purchasing an instrument, we're here to help.